1.
Any Electrical / Electronic Product
Conducted Emission Test
CISPR 11,2010
CISPR 14-1,2009
CISPR 22,2008
CISPR 25,2008
CISPR 15
FCC Part 15 B & 18
BS EN 55011,2007
BS EN 55022:2006+A1:2007
BS EN 55025:2003
BS EN 55015:2006+A2:2009
BS EN 61000-6-3,2007
BS EN 61000-6-4,2007
IEC 61000-6-3,2011
IEC 61000-6-4,2011
BS EN 55014-1,2006
IEC 60601-1-2,2007
IEC 62040-2,2005
EN/ETSI 300 386
IEC 61326,2006
EN 50091-2,1996
GR 1089,2011
SAE J1113-41
(CISPR 14-1 limited to clicks measurement)
 
upto 108MHz
 
Current limitation:
 
16 A for
1f phase
 
32 A for
3f Phase
3.75 dB
2.
Any Electrical / Electronic Product
Radiated Emission Test
CISPR 11,2010
CISPR 25,2008
CISPR 22,2008
FCC part 15 B & 18
BS EN 55022:2006+A1:2007
BS EN 55025:2003
BS EN55011:2007
BS EN 61000-6-3:2007
BS EN 61000-6-4:2007
IEC 61000-6-3:2011
IEC 61000-6-4:2011
IEC 60601-1-2,2007
IEC 62040-2,2005
IEC 62052-11
BS EN 50121-4
AIS 004
EN/ETSI 300 386
BS EN 50091-2,1996
95/54/EC
97/24/EC
2004/104/EC
FORD-ES XW7T-1A278-AC
IEC 61326
GR 1089
SAE J1113-41
 
 
 
upto 7GHz
 
 
 
1m distance
 
 
 
 
3m and 10m distances
 
 
 
 
 
 
 
1.55dB
 
 
 
 
3.62 dB and
3.78 dB
3.
Any Electrical/ Electronic Product
Harmonic Current Emission test
IEC 61000-3-2,2005
BS EN 61000-3-2,2006
IEC 60601-1-2,2007
IEC 62040-2
IEC 61000-6-3,2011
BS EN 61000-6-3,2007
 
16.7 A / phase
 
0.0036  (Deviation @ 3rd Harmonics)
4.
Any Electrical/ Electronic Product
Voltage Fluctuation & Flicker test
IEC 61000-3-3,2008
BS EN 61000-3-3,1995
IEC 60601-1-2,2007
IEC 62040-2
IEC 61000-6-3
BS EN 61000-6-3
 
16.7 A / phase
 
0.076 (Deviation @ 1.0 Hz)
5.
Any Electrical / Electronic Product
RF Radiated Susceptibility Test
BS EN 61000-4-3
IEC 61000-4-3
CISPR 24
BS EN 55024
BS EN 50091-2
BS EN 55014-2
IEC 60601-1-2
BS EN 61000-6-1
BS EN 61000-6-2
IEC 61000-6-1
IEC61000-6-2
IEC 62040-2
IEC 61326
IEC 62052-11
IEEE C37.90.2
95/54/EC
97/24/EC
2004/104/EC
AIS 004
ISO 11452-2
FORD-ES-XW7T-1A278-AC
EN ETSI  300 386
GR 1089
SAE J1113-21
1V/m-15V/m(3m)
 
upto 75V/m(1m)
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
1.039 dB
6.
Any Electrical/ Electronic Product
Electrostatic Discharge immunity test
BS EN 61000-4-2
IEC 61000-4-2
BS EN 55014-2
BS EN 55024
BS EN 50091-2
BS EN 61000-6-1
BS EN 61000-6-2
IEC 61000-6-1
IEC 61000-6-2
CISPR 24
IEC 60601-1-2
IEC 62040-2
IEC 62052-11
IEC 61326
ISO 10605
SAE J1113-13
FORD-ES XW7T-1A278-AC
EN/ETSI 300 386
upto 30KV
 
 
 
± 0.34%
(First Peak Current)
 
± 0.10%
(Rise time)
7.
Any Electrical/ Electronic Product
Electrical Fast Transient  (EFT)/ Burst Immunity test
BS EN 61000-4-4
IEC 61000-4-4
IEC 60601-1-2
BS EN 55014-2
BS EN 50091-2
BS EN 55024
CISPR 24
BS EN 61000-6-1
BS EN 61000-6-2
IEC 61000-6-1
IEC61000-6-2
IEC 62040-2
IEC 62052-11
IEC 61326
IEC 255-22-4
EN/ETSI 300 386
16 A for
1f Phase
 
32 A for
3f Phase
0.015% (Amplitude)
 
0.106%
(Rise time)
 
0.217%
(Pulse width)
 
8.
Any Electrical/ Electronic Product
High Energy/ Telecom Surge Immunity test
BS EN 61000-4-5
IEC 61000-4-5
IEC 60601-1-2
BS EN 55014-2
BS EN 50091-2
BS EN 55024
CISPR 24
BS EN 61000-6-1
BS EN 61000-6-2
IEC 61000-6-1
IEC61000-6-2
IEC 62040-2
IEC 62052-11
IEC 61326
EN/ETSI 300 386
28 A for 1f Phase
26 A for 3f Phase
 
Telecom Surge:
 
0.02%
(Amplitude)
 
0.07%
( Rise time)
 
2.77%
(Pulse width)
 
9.
Any Electrical / Electronic Product
Conducted RF Susceptibility Test
BS EN 61000-4-6
IEC 61000-4-6
CISPR 24
BS EN 55024
IEC 62040-2
IEC 62052-11
BS EN 50091-2
BS EN 61000-6-1
BS EN 61000-6-2
IEC 61000-6-1
IEC61000-6-2
IEC 60601-1-2
EN 55014-2
ISO 11452-4
SAE J1113-4
IEC 61326
EN/ETSI 300 386
GR 1089
1f phase 16A
&
3f phase 32A
150KHz-80MHz,10Vrms
1-400MHz,100mA
2.39 dB
10.
 
Any Electrical / Electronic Product
Power Frequency Magnetic Field Immunity Test
BS EN 61000-4-8
IEC 61000-4-8
BS EN 55014-2
BS EN 55024
CISPR 24
BS EN 61000-6-1
BS EN 61000-6-2
IEC 60601-1-2
IEC 61000-6-1
IEC61000-6-2
IEC 61326
IEC 62040-2
BS EN 50091-2
 
EUT size
1 x 1 x 2.6 mts
 
2.337 dB
11.
Any Electrical/ Electronic Product
Pulse Magnetic field immunity test
BS EN 61000-4-9
IEC 61000-4-9
IEC 62052-11
--
--
12.
Any Electrical/ Electronic Product
Voltage dips, Short Interruption & Voltage Variations Immunity test
BS EN 61000-4-11
IEC 61000-4-11
BS EN 55014-2
BS EN 55024
CISPR 24
BS EN 61000-6-1
BS EN 61000-6-2
IEC 61000-6-1
IEC 61000-6-2
BSEN 50091-2
IEC 60601-1-2
IEC  62040-2
IEC 61326
EN/ETSI 300386
16.7 A / phase
Dip voltage:
1.05% (0%),
1.02% (40%)
1.01% (70 %)
 
Time:
0.03% (0%)
0.63% (40%)
8.7% (70%)
 
13.
Any Electrical/ Electronic Product
Ring Wave/ Damped Oscillatory Wave Immunity test
 
 
BS EN 61000-4-12
IEC 61000-4-12
IEC 60255 – 22 - 1
IEC 62052-11
IEC 255-4
IEC 255-22-1
IEEE C.37.90.1
IEC 61000-4-18
 
For Ring wave
26 A for 1f Phase
28 A for 3f Phase
 
For Damped
16 A per phase
Ring wave:
0.021% (Amplitude)
0.006% (Rise time)
0.010% (Osc. period)
 
Damped:
0.015% (Amplitude)
0.592% (Rise time)
0.082% (Osc. period)
14.
Any Electrical/ Electronic Product
DC Voltage dips, Short Interruption & Voltage Variations Immunity test
IEC 61000-4-29
BS EN 61000-4-29
16.7 A / phase
Dip voltage:
1.0% (40%)
1.0% (70 %)
 
Time:
± 0.23% (40%)
± 0.13% (70%)
15.
Any Electrical/ Electronic Product
Automotive Electrical Transient Immunity Test
ISO 7637-2
SAE J1113-11
FORD-ES XW7T-1A278-AC
2004 / 104 / EC
 
--
12 V system with load:
0.87% (Amplitude)
0.01%( Rise time)
6.45% (time duration)